Web Analytics
Skip to content

Connections ​

Every way data comes into Zora is set up from one screen in the Zora Setup app. Open the Setup app (how) and tap Connections & Sources on its home screen. Each connection tutorial in this group starts here.

The Setup app's home screen
The Setup home screen, with Connections & Sources first

The tabs ​

TabMain Unit V3Main Unit V2What it holds
Hardwareyesnothe server and its modules, as Zora found them
Connectionsyesyesevery data input, with a card for each
GPSyesyeswhich GPS receiver is the primary: see Source priorities
Switchesyesyesdigital switching banks and switch names: see Switches

The screen opens on its first tab. Main Unit V2 has no expansion modules, so it has no Hardware tab. The help button follows the tab you are on.

The tab bar of the Connections & Sources screen
The tabs on Main Unit V3, open on Hardware

Hardware tab ​

The module strip, in physical order: the server first, then slot A, which holds the NVMe module, then the expansion slots B to H. An empty slot is a dashed tile with its letter.

Tap the server or an expansion module to open the Connections tab at that module's group. The NVMe tile does nothing when tapped.

A chip above the strip names how Zora found the modules, with the device type beside it:

ChipHow the modules were foundSlot letters
StackLink detected (green)the server's backplane reports each slotreal
Module EEPROM detected (green)each module reports its own name and slotreal
Probe detected (blue)Zora looked for the interfaces, because neither of the above answeredpositions only
The module strip on the Hardware tab
The Hardware tab, with the chip above the module strip

Under Probe detected, the modules fill the slots from B in the order Zora found them, so a tile's position is not the slot the module is in. A Wireless Mesh module is not shown under Probe detected: its radio cannot be told apart from other Bluetooth hardware.

Specifications: Main Unit V3, Main Unit V2.

Connections tab ​

On Main Unit V3 there is one group per module Zora found: the server, then NVMe, then the expansion modules, each with a picture of the module beside its cards. Main Unit V2 has two groups, NMEA 2000 and Serial & Network.

Each data input is a card. The server's are Network / TCP / UDP, NMEA 2000 / CAN Bus, RS485 / Modbus, RS232 / NMEA 0183 and Digital I/O. On Main Unit V2 there is no Digital I/O card, and only one serial card: RS485 / Modbus or RS232 / NMEA 0183, depending on the mode the serial port runs in. A module with several ports numbers them, as in NMEA 2000 / CAN Bus (1).

Chips on a card say what is live on it:

ChipMeans
the protocol name, greenthe input is switched on. An NMEA 0183 connection with a setting Zora cannot use shows no chip, and its dialog says why
Modbus · 8 relays, greenrelay boards are set up on this RS-485 line, with this many relays
an add-on name, purplethat add-on uses this input

The book button on a card opens the help for that kind of connection.

The server's group on the Connections tab
The server's cards on Main Unit V3, with their chips

Some cards are not data inputs:

  • Simulation plays a recorded file and shows its name. On Main Unit V3 it sits in the NVMe group; on Main Unit V2 in Serial & Network. See Simulation.
  • Zora Cloud carries messages from the iNav4U cloud, such as software update notices, into Zora. It sits in the server's group (Serial & Network on Main Unit V2). Leave it on.
  • USB Speaker, in the server's group (Serial & Network on Main Unit V2), reads On or Off and opens the speaker settings. See USB speaker.
  • The NVMe group shows the disk model and how much of it is used, when it has nothing else to show.

Relay boards on the network is always at the bottom, outside the groups, because a relay board on the boat's network is not wired to any of the server's ports.

If Zora found nothing, the tab reads No data inputs configured.

The connection dialog ​

Tap a card to open its dialog, titled with the module and the input. It has three tabs, Input, Output and Sources. The Simulation dialog has only Input.

Input is what the connection reads. When it has an input set up, three switches come first:

  • Enabled turns the input on or off.
  • Data Logging records the input's raw data. Simulation has no such switch. On NMEA 2000 it appears only while Signal K's NMEA 2000 output is on.
  • Override Timestamps stamps incoming data with Zora's own clock instead of the sender's.

On Main Unit V2 the serial card has one more setting above these switches, Port mode: RS232 or RS485. Zora keeps your choice as soon as you tap it, without Save, and the port changes mode when Zora restarts. Until then the dialog says so and offers Restart Zora Now.

A connection with nothing set up reads No input configured on this connection. RS-485 and the network input are the exceptions: RS-485 relay boards are set up here even without an input, and the network input lists its network connections instead.

The rest of the tab depends on the connection:

The connection dialog of the server's RS232 / NMEA 0183 input
The RS232 / NMEA 0183 dialog, open on its Input tab

Output is what the connection sends. On the network input, NMEA 0183 TCP Output streams NMEA 0183 on TCP port 10110 for chart plotters and other devices on the network. While it is on, you pick the sentences it carries. Each TCP client and UDP connection below it has its own output. An NMEA 0183 connection on a serial port has an Output setting: Off, All sentences or Chosen sentences. Any other input reads No output configured on this connection.

Sources lists the devices Zora has heard on the connection: name, model, type, device number and unique number. On the network input it lists what every network connection has heard. With none heard, the tab reads No sources discovered on this connection.

Press Save to keep your changes. It is inactive until something changes. If the save fails, the dialog stays open and says why. If someone saved the same connection from another device while your dialog was open, nothing is saved: reload the page and make your change again.

After you save ​

A saved connection takes effect when Zora restarts. Until then, Back to Zora on the Setup home screen is orange. Tap it and Setup asks Restart Required: Restart & Go Back restarts Zora and takes you back to it.